-
About Us
- ꀶ Our story
- ꁘ Contact Us
-
Products
- Gas fire extinguishing device series
- Aerosol fire extinguishing device
- High pressure water spray extinguisher
- Superfine dry powder extinguisher
- Foam fire extinguishing agent
- Water fire extinguishing agent
- Water-based fire extinguishers
- Civil building fire ventilation fan
- Factory workshop ventilation/fire valve
- Fire smoke exhaust system &valve
-
Support
- ꀳ Warranty
- ꄆ Download
- Technology
-
Cases
-
FAQ
-
About Us
- ꀶ Our story
- ꁘ Contact Us
-
Products
- Gas fire extinguishing device series
- Aerosol fire extinguishing device
- High pressure water spray extinguisher
- Superfine dry powder extinguisher
- Foam fire extinguishing agent
- Water fire extinguishing agent
- Water-based fire extinguishers
- Civil building fire ventilation fan
- Factory workshop ventilation/fire valve
- Fire smoke exhaust system &valve
-
Support
- ꀳ Warranty
- ꄆ Download
- Technology
-
Cases
-
FAQ
PRODUCT DETAILS
Overview
The Externally Stored Pressure (Reserve Pressure) HFC-227ea Fire Extinguishing System consists of extinguishing agent cylinders, driver gas cylinders, high-pressure metal hoses, check valves (for extinguishing agent pipeline), distribution pipes, safety venting devices, selection valves, signal feedback devices, extinguishing agent delivery pipelines, nozzles, driver gas cylinders, electromagnetic drive devices, driver gas pipelines, check valves (for driver gas pipeline), and other components. The transfer distance of the externally stored pressure system is typically no more than 250 meters.
In the Network-based HFC-227ea Fire Extinguishing System, the extinguishing agent storage cylinders are placed in a dedicated cylinder room and connected through a network of pipes. In the event of a fire, the extinguishing agent is transported from the cylinder room to the protected area through the piping system and released through nozzles to suppress the fire. This system is the preferred choice for multi-zone protection in large buildings, capable of protecting up to eight separate zones simultaneously.
Fire Extinguishing Principle
When the fire suppression system is in automatic control mode, and a fire occurs in the protected area, the fire detectors trigger a fire signal. The alarm controller immediately activates both audible and visual alarms. The gas fire control panel receives two independent fire alarm signals and sends out a linkage command to shut off related equipment. After a 30-second delay, the fire extinguishing command is issued, which opens the corresponding solenoid valve to activate the gas. The activation gas flows through the activation pipeline, opening the appropriate selection valve and container valve of the driver gas cylinders. The driver gas then enters the extinguishing agent cylinder group via the pressure-reducing device, simultaneously opening the agent cylinder group’s container valve. The extinguishing agent is then delivered through the piping network to suppress the fire.
Applications
Suitable for extinguishing the following types of fires:
- Electrical fires
- Liquid fires or fires involving molten solids
- Solid surface fires
- Gas fires that require cutting off the gas supply before suppression
Ideal for protecting enclosed spaces, including the following typical locations:
- Hazardous areas with explosive gases or liquid-type fires
- Libraries, archives, document storage rooms, and museums
- Oil-immersed transformers, distribution rooms with oil-filled switches, and backup generator rooms
- Communication rooms, data centers, and computer rooms
Related Products
-
ꁇGas fire extinguishing device series
-
Single cabinet HFC-227ea extinguishers
-
Double cabinets HFC-227ea extinguishers
-
Pipe network HFC-227ea gas extinguishers
-
External stored pressure HFC-227ea gas
-
Suspended type HFC-227ea gas
-
IG 541 gas fire extinguishing equipment
-
QME 70 carbon dioxide fire extinguisher
-
IG 100 gas fire extinguishing equipment
-
Fire detection tube (Direct type)
-
Fire detection tube (Indirect type)
-
Perfluoroacetone(1230)fire extinguishing
-
Low pressure CO2 fire extinguisher
-
-
ꁇAerosol fire extinguishing device
-
High pressure water spray extinguishing
-
ꁇSuperfine dry powder extinguishing agent
-
ꁇFoam fire extinguishing agent
-
ꁇWater fire extinguishing agent
-
ꁇWater-based fire extinguishers
-
ꁇCivil building fire ventilation fan
-
Cabinet centrifugal fan
-
Backward inclined centrifugal fan box
-
Non volute cabinet centrifugal fan
-
HTF Axial flow fire exhaust fan
-
Mixed flow positive pressure blower
-
PYHL-14A Axial flow fire exhaust fan
-
GXF series inclined mixed positive fan
-
YDF Induction fan
-
DAF Axial flow fire exhaust fan
-
DCF Centrifugal fire exhaust fan
-
FZ fan protective cover
-
SDS Tunnel fan
-
GDF type pipeline centrifugal fan
-
Clean mute blower
-
Silent fan series
-
BLP overhead room ventilator
-
BLD ceiling duct ventilator
-
-
ꁇFactory workshop ventilation/fire valve
-
ꁇFire smoke exhaust system &valve